Grayhot Heating CABLE / MAT


Grayhot Heating CABLE / MAT

Electric warm floor GrayHоt from Odeskabel.

Supplied in the form of ready-to-use products (sections) with a length of 6 to 128 meters, a power of 0.09 to 1.93 kW (220 V)

Поставляется в виде готовых к применению изделий (секций)длиной от 6 до 128 метров, мощностью от 0,09 до 1,93 кВт (220 В)

Application

For heating rooms with low mechanical stress on the cable (class M1).
Operating temperature of cable operation, no more than 65° С. Specific power, max. 15 W / m

Heating cable design

Product Description

A heating cable, in which two conductive cores are made of copper (copper alloys, steel, nichrome), with insulation made of PVC compound of increased heat resistance, with protective elements - an aluminum foil screen, 2 aluminum grounding conductors and a sheath made of PVC plastic compound.
For connection to the network, it has an attached power cable with a cross-section of 3 * 0.75 sq. mm. The tightness class of the connection is IPX7.

Installation and operating conditions

Temperature Range:

  • during installation and laying: not lower than - 5° С;
  • during operation (fixed mounting): from - 40° С to + 50° С;
  • bending radius: at least 6 cable thicknesses;
  • tensile force: no more than 120 N;
  • resistance to deformation by force, for M1 class cables: no more than 600 N.

Standards / TU

TU U 31.3-05758730-029: 2005;
TU U 31.3-05758730-084: 2012
IEC 800

Electrical characteristics

 Article

Length

of cable

Resistance,

Ohm

Power, W
1 0919001 6 529 92
2 0919002 9 376 129
3 0919003 13 261 186
4 0919004 18,5 178 273
5 0919005 23 140 345
6 0919006 29 109 444
7 0919007 34 97,1 498
8 0919008 38 84,7 571
9 0919009 51 64,4 752
10 0919010 59 54,6 886
11 0919011 71 45,3 1068
12 0919012 81 39,7 1219
13 0919013 102 31,6 1531
14 0919014 115 28,1 1725
15 0919015 128 25,1 1929

Deviation from electrical resistance does not exceed minus 5% and plus 10%.

The electrical resistance of the screen to a direct current, recalculated per 1 km of length and a temperature of 20 °C - no more than 34.5 Ohm.

The electrical resistance of the product insulation, measured for 60 seconds with a voltage of 1000 Volts, at a temperature of 20 °C - not less than 1 MΩ.

Marking

2 ‑ х (specific electrical resistance of the conductor Ohm / m) HEATING CABLE ODESKABEL MAX 65 °C

Weight and dimensions

Estimated cable size (reference), mm: 4.5 * 5.5.
Estimated cable weight (reference), kg / km: 28.4.


This site uses cookies.
We use cookies to personalize content and advertising, to provide social networking features and to analyze our traffic. We also transmit information about your use of our site to our partners in social networks, advertising and analytics, which can combine them with other information that you provided to them or which they collected when you use their services.